SPECIFICATIONS : ZEMIC H3 LOAD CELL

Capacity t 0.025 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.5 / 0.6 / 0.75 / 1 / 1.5 / 2 / 2.5 / 3 / 5 / 7.5 / 10 / 15 / 20 / 30
lb 100 / 200 / 250 / 300 / 500 / 750 / 1K / 1.5K / 2K / 2.5K / 3K / 5K / 10K / 15K / 20K
Accuracy C2 C3 C4 A5S A5M B10S B10M
Approval OIML
R60 C3
OIML
R60 C4
Maximum
number of
verification
intervals
n max 2000 3000 4000 5000 5000 10000 10000
Minimum
load cell
verification
interval
v min Emax
/5000
Emax
/10000
Emax
/14000
Emax
/15000
Emax
/15000
Emax
/10000
Emax
/10000
Combined
error
%FS ≤ ±0.030 ≤ ±0.020 ≤ ±0.018 ≤ ±0.018 ≤ ±0.026 ≤ ±0.035 ≤ ±0.050
Creep %FS
/30min
≤ ±0.024 ≤ ±0.016 ≤ ±0.012 ≤ ±0.012 ≤ ±0.017 ≤ ±0.030 ≤ ±0.040
Temperature
effect
on sensitivity
%FS/10℃ ≤ ±0.017 ≤ ±0.011 ≤ ±0.009 ≤ ±0.009 ≤ ±0.013 ≤ ±0.030 ≤ ±0.040
Temperature
effect
on zero
%FS/10℃ ≤ ±0.023 ≤ ±0.015 ≤ ±0.010 ≤ ±0.010 ≤ ±0.014 ≤ ±0.030 ≤ ±0.020
Output
sensitivity
mv/v 2.0 ± 0.004 (Metric) 3.0 ± 0.008 (Imperial)
Input
resistance
Ω 350 ± 3.5
Output
resistance
Ω 351 ± 2.0
Insulation
resistance
≥ 5000 (50V DC)
Zero balance %FS 1.5 (Metric) 1.0 (Imperial)
Temperature,
compensated
-10 ~ +40
Temperature,
operating
-35 ~ +65
Excitation,
Recommended
V 5 ~ 12 (DC)
Excitation,
Max
V 18 (DC)
Safe
overload
%FS 150
Ultimate overload %FS 300